Feature:
1. 600A non‑contact measurement of AC A DC A current does not require disconnection detection, which is safer.
2. High‑accuracy automatic range recognition, measuring the DC current of the car without breaking the line.
3. The fuselage is ergonomically designed, comfortable to hold, practical and beautiful.
4. It can measure DC AC voltage and current, resistance, capacitance, frequency and temperature.
5. Using safe ABS materials, it is not easy to damage the equipment and avoid unnecessary losses.
Specification:
Item Type: Clamp Meter
Material: ABS
Color: Black
Model: ST210
Battery: 1.5V 2 x AAA batteries (not included)
Application: Electrical parameter measurementParameters
Accuracy
6000counts
Resolution
Range
DC Voltage AC Voltage
DC AC6V
+ (0.5percent +3)
0.001V
DC AC60V
0.01V
DC 1000V
0.1V
AC750V
+ (0.8percent +10)
1V
Resistance
600 Ohm
+ (0.8percent +5)
0.1 Ohm
6k Ohm
+ (0.8percent +3)
1 Ohm
60k Ohm
10 Ohm
600k Ohm
100 Ohm
6M Ohm
1k Ohm
60M Ohm
+ (2.5percent +3)
10k Ohm
Capacitance
10nF
+ (3.5percent +20)
10pF
100nF
100pF
1uF
1nF
10uF
10nF
100uF
100nF
1mF
1uF
10mF
10uF
60mF
+ (5percent +3)
100uF
AC and DC Current
60A
+ (2.5percent +30)
0.01A
600A
0.1A
Frequency Measurement
10Hz
+ (0.1percent +3)
0.01Hz
100Hz
0.1Hz
1kHz
1Hz
10kHz
10Hz
100kHz
100Hz
1MHz
1kHz
10MHz
10kHz
Temperature Measurement
( 20 100) celsius
+ (1.0percent +5)<400 celsius ,+ (1.5percent +15) more than 400 celsius
1 celsius
(0 1832) Fahrenheit
+ (0.75percent +5)<750 Fahrenheit ,+ (1.5percent +15) more than 750 Fahrenheit
1 Fahrenheit
.How to Use1 1. Press and hold POWER for more than 2S, and it will display the automatic scanning state when it is turned on.
1 2. Insert the black test into the COM jack and the red test into the V Ohm jack; the test reliably touches the test point.
1 3. When the voltage measured between the input ports COM and VR is greater than 0.8V, regardless of the AC voltage or the DC voltage, the meter will compare the DC component and the AC component, and select the larger component signal. Automatically switch between 6V 60V 600V DC1000V (AC750V) according to the size of the measured value, and then display the measured value on the LCD.
Note:
1) The input voltage must not exceed DC1000V or AC750V, if it exceeds, there is a danger of damaging the meter circuit; when high voltage circuits, pay special attention to avoid electric shock;
2) After completing all measurement operations, disconnect the test s from the circuit under test.
2 1. The automatic scanning state is displayed when the machine is turned on.
2 2. Insert the black test into the COM jack and the red test into the V Ohm jack; the test reliably touches the test point.
2 3. If the measured resistance at both ends of the test is less than 50 Ohm , the buzzer will emit a continuous beep, and fast buzzer measurement is required. Please press the power key to enter the buzzer diode fast measurement.
2 4. If you are measuring closed loop resistance, you must discharge the resistance at both ends of the resistance to be measured. Otherwise, if the voltage in the loop is greater than 0.8V, the meter will mistake it for voltage measurement and enter the voltage measurement mode.
2 5. Input the resistance measurement value between the input port COM and V Ohm , the meter will automatically switch between 600 Ohm 6k Ohm 60k Ohm 600k Ohm 6M Ohm 60M Ohm according to the resistance measurement value, and then the measured value It is displayed on the LCD.
Note:
1) When measuring low resistance, the test s will bring internal resistance. In order to obtain accurate readings, you can record the short circuit value of the test s first, and subtract the value when the test s are short circuited from the measurement reading;
2) When measuring online resistance, all power supplies of the circuit under test must be turned off and all capacitors must be completely discharged to ensure the correctness of the measured value;
4 1. The auto scan status is displayed when the machine is turned on.
4 2. Insert the black test into the COM jack and the red test into the V Ohm jack; the test reliably touches the test point.
4 3. If you need fast continuity test diode capacitance measurement, constantly trigger the power switch, enter the fast continuity test diode capacitance measurement in one cycle, and select the corresponding function measurement according to the measurement requirements. When measuring capacitance , The size of the measured capacitance will automatically select different ranges, and the measured value will be displayed on the LCD. The capacitance measurement range is 10nF 100nF 1uF 10uF 100uF 1mF 10mF 60mF.
Note:
When measuring capacitance in the 10nF range, the value displayed on the screen may have residual readings. This number is the distributed capacitance of the test s and is an accurate reading. After the measurement, the residual reading can be subtracted to obtain an accurate reading.
Package List:
1 x Clamp Meter(Battery Not Included)2 x Test 1 x Temperature Probe1 x Instruction Manual1 x Portable Bag