Feature:
1. TECHNICAL PARAMETERS: The maximum photovoltaic array power is 4000W, the maximum photovoltaic open circuit voltage is 500Vdc, the starting voltage is greater than 150V, the maximum charging current is 100A, and the photovoltaic array MPPT voltage range is from 120 450Vdc
2. PURE SINE WAVE INVERTER: Built in 100A MPPT charge controller, single phase output 230VAC, new integrated inverter, integrating inverter, solar charger and battery charger functions, providing uninterruptible power supply in a single package support
3. ONE KEY RESTORE DEFAULT SETTINGS: All in one MPPT inverter can restore system settings with one key in case of wrong settings, avoid machine damage caused by wrong settings, and automatically restart when AC power is restored to better protect your system
4. SUPERIOR BATTERY PERFORMANCE: 24V inverter is designed with smart battery charger to optimize battery performance; Compatible with mains voltage or generator power
5. DIVERSIFIED USES: Can be connected to various household and office loads, including refrigerators, lamps, TVs, fans, air conditioners and other loads. Supports 4 charging modes: Utility First, Solar First, Solar and Utility, Battery and Solar
Specification:
Item Type: Hybrid Solar Inverter
Inverter Mode:
Rated Power: 3500VA, 3500W
DC Input: 24VDC, 162A
AC Output: 230VAC, 50 60Hz, 15.2A, 1Φ
AC Charging Mode:
AC Input: 230VAC, 50 60Hz, 24.9A, 1Φ
DC Output: 27VDC
Maximum 80A, default 30A
AC Output: 230VAC, 50 60Hz, 15.2A, 1Φ
Solar Charger Mode:
Rated Power: 5000W
Maximum Charger: 100A
Nominal Working Voltage: 240VDC
Maximum Solar Voltage (VOC): 500V DC
MPPT Voltage Range: 120 450VDC
Operating Temperature Range: 10 celsius 50 celsius
Protection Class: IP21
Purpose: This is a multifunctional inverter or charger that combines the functions of an inverter, solar charger and battery charger to provide UPS support in a portable size. Its comprehensive LCD display provides user configurable and easily accessible button operations such as battery charging current, AC or solar charger priority, and acceptable input voltage depending on the application
INVERTER MODEL
3.5KW
Input Voltage Waveform
Sine wave(utility or generator)
Nominal Input Voltage
230Vac
Low Loss Voltage
170Vac+ 7V (UPS);
90Vac+ 7V(equipment)
High Loss Voltage
280Vac+ 7V
Low Loss Return Voltage
180Vac+ 7V (UPS);
100Vac+ 7V (equipment)
High Loss Return Voltage
270Vac+ 7V
Nominal Input Frequency
50Hz 60Hz(automatic detection)
Maximum AC Input Voltage
300Vac
Low Loss Frequency
40+ lHz
Low Loss Return Frequency
42+ lHz
High Loss Frequency
65+ lHz
High Loss Return Frequency
63+ lHz
Output Short Circuit Protection
Circuit Breaker
Efficiency (Line Mode)
>95percent (rated R load, battery fully charged)
Transfer Time
10ms typical (UPS);
20ms typical (device)
Rated Output Power
3.5KW
Output Voltage Waveform
Sine wave
Output Voltage Regulation
230Vac+ 5percent
Output Frequency
50Hz
Peak Efficiency
93percent
Overload Protection
5s at >150percent load; 10s at 110percent 150percent load
Surge Capacity
2 x rated power for 5 seconds
Nominal DC Input Voltage
24Vdc
Cold Start Voltage
23.0Vdc
Low DC Warning Voltage
At load < 50percent
22.0Vdc
At load > 50percent
21.0Vdc
Low DC Warning Return Voltage
At load < 50percent
22.5Vdc
At load > 50percent
22.0Vdc
Low DC Cut off Voltage
At load < 50percent
20.5Vdc
At load > 50percent
20.0Vdc
High DC Recovery Voltage
32Vdc
High DC Cut off Voltage
33Vdc
No Load Power Consumption
<35W
Utility Charging Mode
Charging Algorithm
3 Step
AC Charging Current (Maximum)
80Amp (at Vi P=230Vac)
Bulk Charging Voltage
Flooded Battery
29.2
AGM or Gel Battery
28.2
Floating Charging Voltage
27Vdc
MPPT Solar Charging Mode
Maximum PV Array Power
5000W
Nominal PV Voltage
240Vdc
PV Array MPPT Voltage Range
120 450Vdc
Maximum PV Array Open Circuit Voltage)
500Vdc
Maximum Charging Current (AC charger plus solar charger)
100 Amp
Suggested cable requirement for AC wires
Model
Measurement
Wire Diameter(mm²)
Torsion Value
3.5KW
12 AWG
4
1.2 Nm
Instructions for use:
(1). Connect the power and press the start button(2). LED light indication
LED light indication
Information
AC INV
Green
Long bright
Mains mode power supply
Flicker
Battery or solar powered
CHG
Green
Long bright
Battery fully charged
Flicker
Battery is charging
FAULT
Green
Long bright
Inverter failure
Flicker
Inverter warning starts
(3) Button function description
Function keys
Describe
ESC
Exit setup mode
UP
Skip to last selection mode
DOWN
Skip to next selection mode
ENTER
Confirm selection of setup mode or enter setup mode
.
Package List:
1 x Hybrid Solar Inverter1 x User Manual