Feature:
1. IMPACT RESISTANT HOUSING: Limit switch housing is coated with enhanced PP material, waterproof, oil proof, has higher mechanical strength, impact resistant
2. STABLE AND SENSITIVE: Micro switch adopts thickened copper guide, excellent silver contact, strong conductivity, low resistivity, no arc, stable performance, sensitive contact, with greater bearing capacity
3. RELIABLE SEAL: The travel limit switch has strong sealing performance, and the front and back cover and cylinder block adopt rivet rolling package structure, bring reliable connection
4. SMOOTH OPERATION: Single pole limit switch bring more smooth mechanical action, high toughness, strong fatigue resistance
5. WIDE APPLICATION: Limit switch is widely used in conveyor belt, elevator, parking lot, plastic processing machinery, self assembly machinery, packaging machinery, semiconductor manufacturing, stamping machinery, etc.
Specification:
Item Type: Limit Switch
Rated Voltage: 250VAC
Non Inductive Load:
Resistive Load: NC: 10; NO: 10
Bulb Load: NC: 2.5; NO: 1.25
Inductive Load:
Inductive Load: NC: 10; NO: 10
Motor Load: NC: 3; NO: 1.5
Maximum OF (Maximum): 600g
Minimum RF (Min.): 100g
PT Maximum (Maximum): 2.0mm
OT Minimum (Min.): 6.0mm
MD Maximum (Maximum): 0.8mm
Operating Speed: 0.01mm to 50cm/sec (lock plug type)
Operation Frequency: Mechanical: 120 Times/min, Electrical: 30 Times/min
Contact Resistance: Below 15mΩ (initial)
Insulation Resistance: More than 100mΩ (below 500VDC)
Dielectric Strength:
between discontinuous terminals at 1,000VAC,50/60Hz for 1 minute
On load and no load parts at 1,500VAC,50/60Hz for 1 minute
Between terminal and ground at 1,500VAC,50/60Hz for 1 minute
Vibration: False Action Durability: 10 to 55Hz, 1.5mm double amplitude
Impact: Mechanical Durability: 1,000m/Sec²(about 100G/S); Misoperation Durability: 300m/Sec²(about 30G/S)
Ambient Temperature: When In Use: -10℃~+80℃ (without icing)
Humidity: Service Life:
Machine: 10,000,000 times or more (at rated OT value)
Electrical: More than 500,000 times
How to Use:
1. Inductive Load: Power factor = 0.4; The time constant is 7 msecant.2. The inrush current of the bulb load is 10 times the steady state current. The inrush current of motor load is 6 times that of steady state current.3. With spring series products, the operating body of the range of use from the front end of the spring to the full length of the spring within 1/3.
Package List: